<ErrorNumber>15215</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: conveyor roller motor overcurrent detected
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check conveyer cabling, motor and motor bearing (note ECO's). Check LUE
(only reported if version 6 LUE installed) and check LUE/Conveyer cabling
(note screen cable ECO).
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume if possible. If unable to continue, power off the machine and try again.
If problem persists or recurrs, call Creo service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Conveyer roller motor PWM driver on LUE has reported an over current.
The conveyer current is a digital input on the LUE board. The conveyer motor
driver is also on the LUE board, the driver has a current limit which is set
by fixed resistors on the LUE board.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:57 2008 PST
</Updated>
<Links>
</Links>
</Error>